Agentic AI architecture: what the underlying infrastructure actually looks like

Agentic AI architecture explained from the hardware up: what AI agents ask of GPUs, CPUs, memory, storage, networking, power and cooling in a UK data centre.

Advanced computing infrastructure powering agentic AI agents, automation and complex workloads.

Agentic AI architecture is usually drawn as software: a language model that plans, a memory layer, a set of tools and an orchestrator that runs the loop. Behind these software components sits a demanding physical infrastructure workload. Every agent task triggers many inference calls rather than one, holds data in memory between steps and calls other systems over the network, often around the clock.

This guide summarises the software layers, then sets out what each asks of the hardware, for UK teams deciding where their AI agents will run.

Key takeaways

  • Agentic AI architecture has four core software layers: a reasoning model, memory, tools and orchestration, with guardrails and logging around them.
  • Agents are inference-heavy. One study found tool-using agents made 9.2 times more model calls than single-pass reasoning.
  • Agents need a mix of GPU servers for the model and CPU servers for tools, orchestration and vector search, close together on a low-latency network.
  • The power draw is sustained, not bursty, so the rack power and cooling you can hold all day matters more than headline peaks.

What is agentic AI architecture?

Agentic AI architecture is the design of a system in which AI agents plan and carry out multi-step tasks on their own, choosing which tools to use as they go. The UK government's AI Insights guide on agentic AI defines agentic AI as "AI systems composed of agents that can behave and interact autonomously", with the execution path worked out at runtime by a large language model (LLM) rather than fixed in advance.

Most agentic AI architectures share the same building blocks:

  • Reasoning model. An LLM that interprets the goal, plans the next step and decides which tool to call.
  • Memory. Short-term working state for the current task, plus longer-term memory such as past interactions, user preferences and documents held in a vector database for retrieval.
  • Tools. APIs, databases, search, code execution and business systems the agent can call to act in the real world.
  • Orchestration. The controller that sequences steps, handles retries and, in multi-agent systems, passes work between specialist agents.
  • Guardrails and telemetry. Checks on plans and outputs, permission limits, budgets and logs for audit. A book chapter from Halmstad University sums up this principle as "models propose, architectures dispose".

How agentic AI architecture changes the hardware underneath

Agentic AI turns one request into a loop of plan, act, observe and repeat, so each user task becomes many model calls, tool calls and memory lookups.

Researchers at KAIST measured this directly in The Cost of Dynamic Reasoning, running agent designs on Llama 3.1 8B and 70B models on NVIDIA A100 GPUs. Their findings for tool-using agents compared with single-pass reasoning:

  • 9.2 times more LLM calls per request on average, with one design averaging 71 calls.
  • 3.0 times more KV cache memory per request (the GPU memory that holds the conversation so far), and up to 5.4 times in the worst case.
  • A 62.1 to 136.5 times increase in GPU energy per query for agent-based approaches.
  • GPUs idle for up to 54.5% of execution time on some benchmarks while waiting for tools to return.

The figures come from specific models, hardware and benchmarks, so treat them as a guide rather than a forecast. The pattern is clear: agentic AI infrastructure is sized for sustained inference, not occasional single prompts.

Software layerWhat it doesWhat it asks of the infrastructure
Reasoning modelPlans and decides each stepGPU inference capacity, sustained across many calls per task
MemoryHolds task state, history and retrieved documentsGPU memory for context, plus fast storage and RAM for vector databases
ToolsCalls APIs, databases and codeCPU servers and low-latency links to the systems being called
OrchestrationSequences steps and agents, handles retriesAlways-on CPU capacity and reliable state storage
Guardrails and telemetryChecks outputs, logs every actionExtra model calls and growing log storage

Inference-heavy and always-on: compute for AI agents

AI agents create inference-heavy workloads that, in production, often run continuously rather than in scheduled bursts, generating steady GPU demand for as long as the business is operating. Our AI-ready data centres are built for sustained loads like this, including real-time inference.

Unlike training, which runs flat out for a set period and then stops, agentic AI is planned around sustained throughput: concurrent tasks, model calls per task and how quickly each step must return. The government's AI Insights guide recommends profiling how many parallel requests and concurrent users a system can handle.

Because agents pause while tools run, serving software that batches requests from many agents keeps accelerators busy, provided there is enough GPU memory for the concurrent sessions.

The GPU and CPU mix for agentic AI infrastructure

Agentic AI infrastructure needs both GPU and CPU servers. The model runs on GPUs, but tool execution, orchestration, API gateways, vector search and much of the guardrail logic run on CPUs.

In the KAIST study, tool execution accounted for 30.2% of total latency on average, with LLM inference making up 69.4%. The tool side depends on CPU servers, databases and network links, which are easy to under-provision when budgets focus on accelerators.

Plan GPU and CPU estates together and host them close to each other, ideally in the same hall or cage, so each step of the loop crosses few network hops. Our HPC colocation supports GPU platforms alongside Intel Xeon and AMD EPYC CPU servers.

Memory and storage for agent memory and vector stores

Data centre infrastructure supporting autonomous AI systems and agentic AI architecture.
Data centre infrastructure supporting autonomous AI systems and agentic AI architecture.

Agent memory lives in three places, each with different hardware needs:

  1. GPU memory (KV cache). Holds the context of each active task, and grows with longer sessions and more concurrent agents. The KAIST team found that prefix caching, which reuses shared prompt context, cut average KV cache use by 51.7%.
  2. Vector databases. Store embeddings of documents and past interactions for retrieval. These are typically held in RAM or on fast NVMe flash, so lookups return quickly within each loop step.
  3. Logs and episodic memory. Every plan, tool call and output is logged for audit, which grows steadily and needs durable, backed-up storage.

Agent memory often holds customer data or internal records. Keeping GPUs, vector stores, and logs in one UK facility makes it simpler to say where that data sits, though your data protection lead should confirm your obligations.

Latency and networking for AI agents

Latency compounds in agentic AI because every step of the loop waits for the one before. An agent that makes 10 model calls and 10 tool calls pays for 20 round trips. In the KAIST study, each Wikipedia API call alone averaged 1.2 seconds.

Three network decisions make the biggest difference:

  • Keep the model near the data. If the agent queries your ERP, CRM or data warehouse at every step, host the inference servers close to those systems or on direct links to them.
  • Use private links to cloud services. If agents call cloud-hosted APIs or models, cross-connects to cloud on-ramps avoid routing every call over the public internet.
  • Avoid contended bandwidth. Agents make many small, frequent requests, so consistent latency matters more than peak speed.

Our carrier-neutral connectivity offers cross-connects to cloud on-ramp providers, uncontended bandwidth and diverse routing.

Power and cooling for agentic AI workloads

Agentic AI workloads draw high, steady power, so the question to ask a data centre is how much power per rack it will sustain all day without capping or throttling. An eight-GPU H100 server draws around 5.6kW, and a rack of them quickly passes the 5kW to 15kW that most enterprise air cooling was designed for.

The KAIST researchers projected this at scale. Counting GPU energy only, serving 71.4 million agentic queries a day with a 70B model needed roughly 0.5GW to 1.0GW depending on the agent design, against about 7.6MW for the same number of ordinary chat queries. The scenarios are simplified, but they show why agents raise the power and cooling bar.

At these densities, liquid cooling becomes the norm. Direct-to-chip cooling uses cold plates on the CPUs and GPUs to remove heat at the source, and immersion suits the densest deployments.

Example: a UK insurer plans a claims agent that makes around 10 model calls and several database lookups per claim. At 20,000 claims a day, that is about 200,000 inference calls daily, running through office hours and overnight batches. The plan becomes steady GPU capacity, CPU nodes for the claims system integrations, fast storage for a policy document vector database, and racks cooled for continuous use.

Cloud, colocation or on-premises for agentic AI?

Steady, always-on agent workloads usually favour dedicated hardware in colocation, while short experiments and spiky pilots often suit the cloud. A sensible pattern is to prototype on cloud APIs, then move production inference onto your own GPUs once volumes are predictable. Our guide to colocation vs cloud covers that decision workload by workload. For UK buyers, data centres were designated Critical National Infrastructure in September 2024, which brings government support for the sector during incidents such as cyber attacks and outages.

What to ask a data centre before hosting AI agents

High-performance servers connecting AI agents, computing resources and intelligent automation.
High-performance servers connecting AI agents, computing resources and intelligent automation.

Before committing agentic AI infrastructure to a facility, ask:

  1. What sustained power per rack can you deliver, and is it ever derated or capped?
  2. Which cooling options are available, and can air, direct-to-chip, and immersion sit in the same facility as your estate grows?
  3. Can GPU and CPU servers sit in the same cage or hall to keep the agent loop on short network paths?
  4. What connectivity is available, including carriers, cross-connects and private links to cloud on-ramps?
  5. Are engineers on site, and is power billed by space or by consumption?

We provide UK colocation for GPU clusters and real-time inference from our Swindon facility, with resident on-site engineers, liquid cooling options and power-based billing.

Frequently asked questions

Do AI agents need GPUs?

AI agents need GPUs if you run the language model yourself, because LLM inference is far faster on accelerators. If your agents call a hosted model through an API, the GPUs sit with that provider, and your estate mainly runs CPU servers for orchestration, tools, and vector search. Many production systems use both.

How is agentic AI architecture different from a chatbot?

A chatbot usually answers each prompt with a single model call. An agentic AI architecture plans a goal, calls tools, checks the results and repeats until the task is done, so one request can trigger dozens of model calls. That loop drives the extra GPU, memory, and network demand.

What hardware does a vector database need?

A vector database for agent memory needs plenty of RAM and fast NVMe storage so retrieval returns within each step of the agent loop. Most run on CPU servers, though some use GPUs to speed up search. Size it for document volume and the number of agents querying it.

Can smaller models reduce agentic AI infrastructure needs?

Smaller models can considerably reduce agentic AI infrastructure needs. In the KAIST study's energy tests, the 8B model used roughly a seventh to an eighth of the GPU energy per query of the 70B model for each agent design measured. The government's AI Insights guide also suggests mixing local and remote LLMs, and routing simpler steps to a smaller model is one way to do that.

Planning infrastructure for agentic AI architecture

Agentic AI architecture looks like software on a whiteboard. Still, in production it is a sustained inference workload that needs GPUs and CPUs side by side, fast memory and storage, short network paths, and power and cooling that hold up all day.

If you are planning infrastructure for AI agents, book a power assessment, and we will review your rack densities, cooling needs, and how power-based billing would work for your estate.

Related articles

High-density rack colocation: a UK guide from 4kW to 200kW+ per rackHigh-density rack colocation explained band by band, from 4kW to 200kW+ per rack: typical workloads, cooling methods, power and floor needs, and how to choose.Scalable AI infrastructure: how to grow without migratingScalable AI infrastructure lets you expand AI workloads without migrating. Discover how to plan power, cooling, networking and capacity for future growth.What is AI infrastructure? A UK buyer's guide for 2027What is AI infrastructure? An easy-to-read UK guide to the compute, storage, networking, power and cooling AI needs, and whether to use cloud or colocation.Data centre tiers explained: what Tier 3 and Tier 4 mean when you choose colocation.Data centre tiers explained: what Tier I to IV mean, how Tier 3 and Tier 4 differ, what the uptime percentages really are and how to check a tier claim.NVIDIA Vera Rubin: What UK Data Centres Need to Host ItNVIDIA Vera Rubin NVL72 racks can draw over 200kW and need 100% liquid cooling at up to 45°C. See what a UK data centre needs to host Vera Rubin.What is N+1 redundancy, and is it enough for your servers?What is N+1 redundancy? Understand how it protects servers, how it compares with 2N, its limits, and what to ask when choosing a colocation provider in the UK.What is PUE, and what does it mean for your colocation power bill?What is PUE? See how power usage effectiveness is calculated, what a good data centre PUE looks like and how it can influence your UK colocation power costs.UK vs US Data Centres: The Water Usage DifferenceHow UK and US data centres compare on water use: climate, cooling architecture, Thames Valley pressure, and where liquid cooling changes the equation.What Is AI Actually Used For?Four categories of AI workloads, where they run in the UK, and what each one actually demands of the data centre underneath. Written for infrastructure buyers.How Does Colocation Work?Colocation works by moving your own servers, storage and networking equipment into a professionally managed data centre. You continue to own and control…A Guide to Server Rack Sizes for Data CentresServer rack sizes are usually described in rack units, or U. One rack unit provides 1.75 inches, or 44.45 mm, of vertical mounting space, while most…How to Improve Network Latency in ColocationTo improve network latency in colocation, start by measuring where the delay actually occurs. Establish normal round-trip times, trace the routes between…Increasing Server Capacity Without Creating a New BottleneckIncreasing server capacity is not simply a matter of adding more CPU, memory or another server. The first step is identifying what is actually limiting…Data Centre Migration Checklist - How to Plan a Low-Risk MoveUse this data centre migration checklist to plan dependencies, power, connectivity, rollback and validation for a lower-risk move.How Much Does Immersion Cooling Cost? Capex, Opex, and TCO ExplainedSee what drives immersion cooling cost in the UK, from CapEx and OpEx to TCO, and compare the real cost of supporting high-density compute.What Is a Coolant Distribution Unit? A Data Centre CDU GuideWhat is a coolant distribution unit? Learn how CDUs manage coolant flow, heat transfer, and pressure in liquid-cooled data centres.AI Colocation in the UK: How to Choose Infrastructure That Will Not Hold Your GPUs BackCarbon-Z delivers AI colocation in the UK with liquid cooling up to 120kW per rack. Built for GPU clusters, AI training, and sustained high-density workloads.From 8kW To 120kW: When Your GPU Cluster Outgrows Standard ColocationGPU clusters scaling from 8kW to 120kW often outgrow standard colocation. Learn the warning signs and what infrastructure changes are needed for dense compute.Liquid Cooling For Data Centres: A Buyer's GuideLiquid Cooling for Data Centres explained. Compare cooling options, buyer checks and key questions before planning high-density infrastructure.What 120kW Per Rack Actually Looks Like: Power, Cooling, And Cabling SpecificationsSee what 120kW per rack means for power, cooling, cabling and monitoring before planning high-density data centre infrastructure.Are Colocation Data Centres the Same as Servers?Colocation data centres and servers fill different roles in IT infrastructure. Learn how each works, when colocation is the right choice and what to look for.Carrier-Neutral Data Centre Benefits: Why Network Choice MattersExplore carrier-neutral data centre benefits, from provider choice and route diversity to stronger hybrid connectivity.What Is Immersion Cooling? A Practical Guide for High-Density InfrastructureWhat is immersion cooling? Learn how it works, when it makes sense, and how it supports high-density infrastructure.How to Improve Network Resilience in Data CentresHow to improve network resilience in data centres through diverse connectivity, tested failover, configuration control and wider observability.Where to Colocate in the UK: A Guide to the Top Data Centre HubsChoosing a UK colocation hub now turns on power and cooling, not postcode. We map the four hub types and how to match each to your workload.Why AI and HPC Workloads Need Immersion CoolingAI and HPC racks now draw 40 to 140 kilowatts. We explain why air cooling has hit its ceiling and where immersion genuinely earns its place.What Does It Actually Cost to Run an AI Model?Running an AI model costs more than most organisations expect. We break down GPU hardware, power, cooling, and egress to show where the money actually goes.What Is Colocation? The Complete UK Guide 2026UK colocation services explained: costs, cooling, security, cloud comparisons and how to choose a provider. Written by engineers who run the facilities.Air Cooling vs Liquid Cooling: Which Does Your Infrastructure Actually Need?Air cooling vs liquid cooling: which does your infrastructure need? We break down rack density, PUE, and total cost to help you make the right call.Colocation vs Cloud - Where Your Workloads Actually BelongColocation vs cloud isn't a philosophy debate. We break down the real cost, compliance, and performance factors that determine where your workloads belong.The thirst for AIAI is revolutionary in its capabilities. It is becoming integrated to all the applications that we use…Combating obsolete Data CentresDive into how immersion cooling slashes energy use and unlocks high rack densities for AI, GPU and HPC workloads.Open DayExciting News! Join us for a Journey into the Future of Hosting and Cooling at Swindon Data Centre Open Day!AtomsCarbon-Z Atoms are modular, build-on-demand data centre units with up to 1MW capacity and flexible cooling options built for rapid deployment and scalability.

Ready to upgrade your infrastructure?

Stop overpaying for legacy efficiency. Get a quote for colocation, immersion or a custom build in under 24 hours.

Talk to an engineer

Trusted by tiered vendors

Midas Immersion logoVirgin Media Business logoSubmer logoIntel logoWifinity logoValvoline Global logo
Call